Property | Description/Value |
---|---|
Operating environment |
Outdoor use |
Use in wet location |
Yes |
Operating temperature |
−40 … +55 °C (−40 … +131 °F) |
Storage temperature |
−40 … +70 °C (−40 … +158 °F) |
Operating humidity |
0 … 100 %RH |
Pollution degree |
2 |
Maximum operating altitude |
2000 m (approx. 6500 ft) |
IP rating |
IP67: Dust-tight. Protected from the effects of temporary immersion in water under standardized conditions of pressure and time. |
Property | Description/Value |
---|---|
Operating voltage | 9 … 32 V DC |
Current consumption, maximum | 2 A |
Mating connector (power input) | M12 A‑coded 4‑pin female |
Property | Description/Value |
---|---|
Processor | ARM Cortex A9, 800 MHz |
Memory | 1 GB DDR3L RAM, 8 GB eMMC Flash |
Operating system | Linux |
Communications protocol | IPv4 |
Property | Value/Description |
---|---|
Acceptance | CE (Europe), EAC/CE (Ukraine), FCC (USA), IC (Canada), RCM (Australia and New Zealand), Giteki (Japan) 1 |
SIM card type | Mini-SIM |
Frequency bands | |
LTE-FDD | B1/ B2/ B3/ B4/ B5/ B7/ B8/ B12/ B13/ B18/ B19/ B20/ B25/ B26/ B28 |
LTE-TDD | B38/ B39/ B40/ B41 |
WCDMA | B1/ B2/ B4/ B5/ B6/ B8/ B19 |
GSM | B2/ B3/ B5/ B8 |
Property | Description/Value |
---|---|
Weight | 1 kg (2.2 lb) |
Package dimensions (L × W × H) | 306 × 184 × 156 mm (12.05 × 7.24 × 6.14 in) |
Mating connectors (sensor input) |
|
Material, enclosure | Polycarbonate (PC) |
Material, connectors | Nickel-plated brass |
Test | Standard |
---|---|
EU directives and regulations |
EMC Directive (2014/30/EU) Low Voltage Directive (2014/35/EU) Radio Equipment Directive, RED (2014/53/EU) RoHS Directive (2011/65/EU) amended by 2015/863 |
EMC compatibility |
EN 61326‑1, industrial environment CISPR 32 / EN 55032, Class B EN 301 489-1 FCC part 15 B, Class B ICES‑3 / NMB‑3 (Class B) |
Radio compatibility |
EN 301 908-1 EN 301 511 FCC part 22, 24, 27, 90 |
Electrical safety |
EN 61010‑1 |
Cold |
IEC 60068‑2‑1 |
Dry heat |
IEC 60068‑2‑2 |
Vibration |
IEC 60068‑2‑6 IEC 60068‑2‑64 |
Change of temperature |
IEC 60068‑2‑14 |
Damp heat, cyclic |
IEC 60068‑2‑30 |
Rough handling |
IEC 60068‑2‑31 |
Damp heat |
IEC 60068‑2‑78 |
Corrosion and salt mist |
VDA 621‑415 |
Freezing rain | NWS 8.0 |
Compliance marks |
CE, EAC/CE, FCC, IC, RCM, UKCA |
- 1
- Power+
- 2
- RS‑485−
- 3
- GND
- 4
- RS‑485+