Enabling and disabling sensors - AWS810

AWS810 Configuration and Maintenance Guide

Document code
M212419EN
Revision
H
ft:locale
en-US
Product
AWS810
Document type
User guide

To take a new sensor into use after the initial configuration, install the sensor and enable it in the Web UI. The sensor parameters to be enabled are located in the features parameter group.

If a sensor is malfunctioning, you can disable it in the configuration to stop the related error messages.

Sensor parameters
Parameter name Sensor
BARO_1 Pressure Sensor BARO‑1
CEILO_1 Ceilometer CL31
HMP_D_1 Humidity and Temperature Probe HMP155 (analog)
HMP_S_1 Humidity and Temperature Probe HMP155 (serial)
NMEA_WIND_1 WINDCAP Ultrasonic Wind Sensor WMT700
NMEA_WIND_2 Secondary WINDCAP Ultrasonic Wind Sensor WMT700 (if using 2 wind sensors)
NR_D_1 Net Solar Radiation Sensor NR Lite2
PLUVIO_1 Precipitation Gauge OTT Pluvio2 L
PTB_1 BAROCAP Digital Barometer PTB330
PWD_1 Present Weather Detector PWD22
SDUR_D_1 Sun Duration Sensor CSD3
SR_D_1 Pyranometer SP Lite2
SR_S_1 Pyranometer SMP3/SMP6 (Modbus)
SR_S_2 EKO MS Series Pyranometer (interface only)
TIPPING_BUCKET_1 Rain Gauge SBS314
TS_D_1 Soil Temperature Sensor QMT110
UV_D_1 UV Radiometer SUV5
WXT_1 WXT530 Series Weather Transmitter
  1. In the Web UI, go to Settings > Station parameters.
  2. Under the parameter group features, locate the parameter of the sensor you want to enable, for example, WXT_1 for WXT530 Series Weather Transmitter.
  3. To enable a sensor, set the Active value of the parameter to on.
  4. To disable a sensor, set the Active value of the parameter to off.
  5. To save the changes and take them into use, select Save and restart script.