Powering and transient protection spare parts and components - AWS810

AWS810 Configuration and Maintenance Guide

Document code
M212419EN
Revision
H
ft:locale
en-US
Product
AWS810
Document type
User guide
To maintain product safety, replace safety-critical components only with the spare parts listed in the following table. Follow the replacement instructions carefully.Spare parts for powering and transient protection components
Item Safety-critical Order code
Phoenix Contact QUINT4-PS/1AC/24DC/10 AC/DC power supply unit (240 W) Yes 271495SP
Phoenix Contact QUINT4-PS/1AC/24DC/20 AC/DC power supply unit (480 W) Yes 271496SP
12 V / 24 Ah VRLA battery set Yes 275547SP
12 V / 28 Ah VRLA battery set Yes 275965SP
Battery Management Unit BMU801 Yes BMU801SP
BMU801 connector set No 276410SP
BMU801 NTC resistor No 275647
Solar panel 70 W with frame, set of mounting kits, and cable No 267871

Surge protector:

  • Surge protection plug (Phoenix Contact 2907923)
  • Surge protection socket (Phoenix Contact 2907924)
Yes

 

  • 254404SP
  • 254402SP
Ethernet surge protector No 262719SP
Circuit breaker for external DC or WMT700 heating Yes 278844
Circuit breaker for OTT Pluvio2 L heating Yes 278842
Circuit breaker for enclosure heating Yes 278631
Enclosure heater without mounting plate or electronics Yes ASM213618
Heating control relay, 24 V DC Yes 214992SP
Thermostatic switch Yes 12576
TERMBOX‑1200 with 1 data line No TERMBOX-1200SP
TERMBOX‑1212 with 2 data lines No TERMBOX-1212