You can configure GOES data message to be sent automatically to the GOES link if you have a GOES transmitter in the weather station.
By default, GOES transmission bit rate is set to 300 bps and transmission is centered, that is, occurs in the middle of the transmission window. The transmission interval is set to 1 hour.
- In the Web UI, go to Settings > Station parameters.
- Under the parameter group features, set the Active value to on for the parameter GOES_1.
-
To save the changes and take them into use, select Save and restart
script.
When the script has restarted, refresh the browser to get the changes visible.
-
Find the parameter group goes_1 .
-
Type the GOES transmitter identifier in the following parameter:
- transmitterId
- Unique transmitter identifier (8 hexadecimal digits). Provided by the satellite service operator.
-
Configure the following settings for the timed (primary) message. The settings are
provided by the satellite service operator.
- primaryBitRate
- Assigned transmission bit rate for timed messages
(default =
300
). - primaryChannel
- Number of the assigned transmission channel for timed messages.
- primaryTransmitInterval
- Assigned transmission interval for timed messages.
- primaryTransmitTime
- Assigned transmission time for timed messages.
- primaryTransmitWindow
-
Assigned transmission window length for timed messages.
For example, if the transmission interval is
01:00
(hh:mm), transmission time00:16
(hh:mm), and transmission window00:10
(mm:ss), the timed (primary) messages are transmitted once per hour, within 10‑seconds window that starts 16 minutes past the full hour. - primaryTransmitEnabled
- Select true to enable transmission of timed (primary) messages.
-
Configure the following settings for random (secondary) message.
Transmitting of random (secondary) messages is not part of the standard AWS810 configuration by default. Configure these parameters only if your system uses random (secondary) messages. - secondaryBitRate
- Transmission bit rate for random messages (default =
300
). - secondaryChannel
- Number of transmission channel for random messages.
- secondaryTransmitdelay
- Time delay from message creation to transmission start.
- secondaryTransmitRepeat
- Number of transmission repeats, that is, how many times the message is sent.
- secondaryTransmitInterval
-
Interval for transmission repeats.
For example, if the transmission delay is
00:10:00
(hh:mm:ss), transmission repeat2
, and transmission interval00:05
(hh:mm), the random (secondary) message transmission starts 10 minutes after the message has been created and gets sent twice with an interval of 5 minutes. - secondaryTransmitEnabled
- Select true to enable transmission of random (secondary) messages.
-
Configure the following common settings for GOES connection.
- centerTransmit
-
- true (default): Transmission of the timed (primary) message occurs centered to the given transmission time window. If the transmission takes, for example, 4 seconds and the window length is set to 10 seconds, a centered transmission starts 3 seconds after the scheduled transmission time. Vaisala recommends to use this option.
- false: Transmission of the timed (primary) message starts at the beginning of the given transmission time window, that is, at the scheduled transmission time.
- maxTimeDiff
- Allowed system time error (in seconds) before adjusting time from the transmitter's GPS.
- pollInterval
-
Forced transmitter polling interval (default =
1:00:00
).You can edit the polling interval to provide value updates more frequently, for example during commissioning and troubleshooting. - rfPowerReduction
- RF power reduction in 0.5 dB steps.
0
= Full power.
- To save the changes, select Save.