EKO MS series
pyranometer is connected to the DMU801 data management unit through port D4.
The factory default Modbus address of the EKO MS sensor equals the last 2 digits of the
sensor serial number. Set the Modbus address in the station parameters.
-
In the Web UI, go to .
-
Locate the sr_s_2 parameter group on the parameter list.
-
In parameter address, change the value to be the last 2 digits of the EKO MS sensor serial number.
-
(Optional) In parameters instrument_manufacturer and instrument_model, type the model and manufacturer name of the sensor.
-
(Optional) In parameter allow_hotplug, change the value if needed. Allowing hotplug means that you can replace the sensor and
the weather station detects it even without a restart. The feature is enabled by default.
-
To save the changes and take them into use, select Save and restart
script.