Adding anti-freeze solution - AWS810

AWS810 Configuration and Maintenance Guide

Document code
M212419EN
Revision
H
ft:locale
en-US
Product
AWS810
Document type
User guide
The freezing of the collected precipitation of > 200 mm (7.87 in) deforms the collecting bucket floor, tips the bucket, and makes the bucket lean against the pipe housing (force shunt). This causes inaccurate measurement results.

To prevent the collecting bucket floor from deforming if the collected precipitation freezes in sub-zero temperatures, add anti-freeze solution. The manufacturer recommends that you use Thermoschema's POWERCOOL DC 924-PXL.

For the correct proportion of anti-freeze solution and information on using other anti-freeze solutions than POWERCOOL DC 924-PXL, see OTT Pluvio2 L Precipitation Gauge Operating Instructions.

CAUTION Always dilute the anti-freeze solution before adding it. Anti-freeze solutions have hygroscopic properties.

If necessary, after precipitation make sure manually that the anti-freeze solution is well mixed in the collecting bucket. Vibration caused by manual mixing may temporarily produce incorrect results.

Do not pour the anti-freeze solution to the public sewer system. Contact your local authorities regarding the correct disposal.