Connecting sensor cables - AWS810

AWS810 Installation Guide

Document code
M212418EN
Revision
G
Language
English
Product
AWS810
Document type
User guide
  • Flat head screwdriver (optional)
CAUTION To avoid strain on the connector, make sure you connect the cable properly. Too much strain may cause the cable to fall off, damage the cable or connector, or make the cable or connector susceptible to water leakage.

After preparing the sensor cables, connect the cables to DMU801 plug‑in modules.

  1. Turn the 2 orange lock levers of the connector to the open or middle position.
    1
    Open
    2
    Middle
    3
    Locked
  2. Insert the connector in the correct port in the DMU801 plug-in module.
  3. Push the connector to the bottom of the port.
    CAUTION Make sure that the lock levers are in the open or middle position. Pushing the connector in place with the lock levers in locked position will damage the lock levers.
  4. Verify that both lock levers have turned to the locked position, or turn them manually.
    CAUTION Do not use force. If the lock levers do not turn to the locked position easily, it means that the connector is not properly in place.