Connecting Termbox AC (mains) cable - AWS810

AWS810 Installation Guide

Document code
M212418EN
Revision
G
Language
English
Product
AWS810
Document type
User guide
WARNING Do not replace the AC (mains) cable with an inadequately rated cable.
Make sure that the AC (mains) cable material is suitable for the same maximum temperature as the device or system it is used with.
  • 20‑mm and 32‑mm wrench
  1. Install the surge protector.
  2. Take the AC (mains) connection out from Termbox through the CG2, CG3, and CG4 cable glands. CG2 is reserved for the thick outgoing cable.
  3. Connect the outgoing wires with the 5 rightmost points in the terminal connector block: L2, L3, L, N, and PE.
  4. Depending on the Termbox model, connect the signal cables directly to the screw terminals of the connector block or to the protection component.
    • CG5 and CG7 are for incoming cables.
    • CG6 and CG8 are for outgoing signal cables.
For information on the signal line connections, see TERMBOX-9000, 1200, 1212, 1222 User Guide (M210310EN).