Installing NR Lite2 - AWS810

AWS810 Installation Guide

Document code
M212418EN
Revision
G
Language
English
Product
AWS810
Document type
User guide
  • 5‑mm Allen key
  • 13‑mm wrench

Install NR Lite2 1.5 … 3 m (4 ft 11 in … 9 ft 10 in) above the ground.

For the most reliable measurements:

  • Make sure that nothing obstructs the sensor during the day.
  • Avoid reflective surfaces near the sensor. These include radiation shields of the weather transmitter or temperature and humidity sensor, for example.
Figure 1. NR Lite2 installation accessories
1
NR Lite2
2
Mounting bracket
3
Nut M8 DIN985 A4 (4 pcs)
4
Spring washer B8 DIN127 A4 (4 pcs)
5
Flat washer A8,4 DIN125 A4 (4 pcs)
6
Support arm
7
Flat washer A6,4 DIN125 A4 (4 pcs)
8
Spring washer B6 DIN127 A4 (4 pcs)
9
Hex screw M6×60 DIN912 A4 (4 pcs)
To prevent corrosion, oxidation, and seizing, use a non‑conductive, non‑water‑soluble, non‑silicone‑based grease, such as ceramic or Teflon paste, between different kinds of metal.
  1. Loosen the installation bolts and slide the mounting bracket onto the support arm.
  2. Tighten the installation bolts. Tightening torque 5 Nm.
  3. Loosen the U‑bolt nuts and slide the pyranometer through the U‑bolts.
  4. Tighten the U‑bolt nuts.
  5. Check that the pyranometer is level.