Mounting Termbox on frangible lattice mast - AWS810

AWS810 Installation Guide

Document code
M212418EN
Revision
G
Language
English
Product
AWS810
Document type
User guide
  1. Open the Termbox cover.
  2. Attach Termbox to the mast adapter.
    1
    Hex screw M6×20 DIN912 (4 pcs)
    2
    Flat washer A6.4 DIN125 A4 (4 pcs)
  3. Attach the Termbox cover back to its place.
  4. Attach the mast adapter to the mast. Tightening torque 5 Nm.
    1
    Hex screw M6×70 DIN912 (4 pcs)
    2
    Flat washer A6.4 DIN125 A4 (4 pcs)