Mounting WMT700 on support arm using WMT70FIX - AWS810

AWS810 Installation Guide

Document code
M212418EN
Revision
G
Language
English
Product
AWS810
Document type
User guide
  • 5‑mm Allen key
  • 13‑mm wrench

When you mount WMT700 on a horizontal support arm using the WMT70FIX mounting kit, place WMT700 with the array facing up.

  1. Make sure that the cable is firmly connected to the sensor.
  2. Attach the WMT70FIX mounting kit to the support arm with the U‑bolts and insert the U‑bolts in the slots of the mounting kit.
  3. Check that the mounting kit is not tilted to either side and tighten the U‑bolts firmly.
  4. Lift the sensor up.
  5. Holding the sensor from its body, run the cable through the mounting kit, and slide the sensor into the mounting kit.
  6. To avoid misalignment, turn the sensor until the screw reaches the far end of the slot, and tighten the screw. Tightening torque 5 Nm.
    1
    WMT700 mounting screw
    2
    U‑bolt and nut (M8 DIN934 A4) in horizontal slot
  7. Align the sensor.