The weather station enclosure is installed on a mast. The following guidelines apply:

  • The enclosure is installed at eye height. The radiation shield protects the enclosure from direct sunlight and must always be used.
  • The pressure sensor is located inside the enclosure.
  • Most sensors are installed on the mast or on the support arm. The following are exceptions:

    • Precipitation sensor and ceilometer are mounted on individual pedestals away from the mast.
    • Ground sensors and subsurface sensors are installed some distance from the mast.
CAUTION To ensure system operability, install the sensors close to the mast. This reduces the risk of low signal quality as well as operating and heating voltage loss.
Figure 1. Recommended site layout with distances. The following figure shows the recommended site layout. If your site layout requires different placements, prepare for them when ordering your equipment by, for example, planning for different cable lengths. For more information about available options for each sensor, see the relevant sensor documentation.
1
Object of height H
2
Minimum distance to the object is 10 × H
3
Maximum distance to rain gauges is 6 m (19 ft 8 in)
4
Maximum distance to ceilometer and FD70 is 8 m (26 ft 3 in)
5
Maximum distance to subsurface sensors is 10 m (32 ft 10 in) or 35 m (114 ft 10 in) with an extension cable