Enclosure ENC652 houses the DMU801 data management unit and other system components, including internal wiring.
The enclosure is stainless steel and has IP66 rating. The enclosure has a mounting frame for easy installation on a mast. A cabling box at the bottom of the enclosure protects the cable connections from vandalism and other external disturbances. There are 2 flanges for cable feed-through at the bottom of the enclosure.
The following figure illustrates AWS810 components inside the enclosure. Some of the components are optional.
- 1
- Enclosure ENC652
- 2
- Backup battery 12 V / 24 or 28 Ah
- 3
- Digital barometer PTB330
- 4
- Optional backup battery 12 V / 24 or 28 Ah
- 5
- Battery mounting clamp
- 6
- Backplate
- 7
- DC terminal box assembly
- 8
- Ethernet surge protector
- 9
- Battery management unit BMU801
- 10
- Data management unit DMU801
- 11
- Door switch
- 12
- Cabling box
- 13
- Rubber or stainless‑steel flange (2 pcs)
- 14
- DC/DC converter
- 15
- Pressure port
- 16
- External DC or sensor heating circuit breakers
- 17
- Radiation shield
- 18
- Sensor grounding rail
- 19
- Type label
- 20
- Communication device, such as leased-line modem or GOES transmitter (optional)
- 21
- AC/DC power supply
- 22
- AC (mains) input assembly