  • When using MD30 with Vaisala Wx Horizon and RoadAI, the default settings are the following (not adjustable):

    • The data transfer interval from the mobile sensor to Wx Horizon or RoadAI is 100 ms.
    • The RoadAI phone app shows data with a 200 ms interval.
  • When implementing the MD30 interface, you can set the data transfer interval from the mobile sensor to the data collection system to 25 ms ... 5 s. For more information, see Vaisala Mobile Detector MD30 Interface Description.
Table 1. MD30 measurements
Measurement parameter Unit 1 Description/Value Measurement interval
Grip 0 ... 1 25 ms
Surface state

Dry, moist, wet, snowy, icy, slushy

25 ms
Surface layer thickness mm/in 25 ms
Surface temperature °C/°F

Freely configurable offset 1

150 ms
Air temperature °C/°F

Freely configurable offset 1

1 s
Dew/frost point temperature °C/°F 1 s
Relative humidity %RH 1 s
1 Available in MD30 interface.