Before connecting wires or cables, make sure that the transmitter is powered off.
Analog outputs are not available in transmitters that are powered with Power over Ethernet (PoE).
Use the touchscreen or web interface to change the output mode (for example, 0 … 5 V or 4 … 20 mA) and scaling of the analog outputs.
For the M20×1.5 cable gland ordered together with the transmitter from Vaisala, the cable diameter is 5.0 … 8.0 mm (0.20 … 0.31 in). Tightening torque for the cable gland is 8 Nm.
For the M20×1.5 cable gland with split bushing, the cable diameter is 7 mm (0.28 in).
Terminal | Function | Notes |
---|---|---|
CH1 + | Analog output channel 1 + | Max. wire size: 2.5 mm2 (14 AWG) |
CH1 - | Analog output channel 1 - | |
CH2 + | Analog output channel 2 + | |
CH2 - | Analog output channel 2 - | |
CH3 + | Analog output channel 3 + | |
CH3 - | Analog output channel 3 - | |
CH4 + | Analog output channel 4 + | |
CH4 - | Analog output channel 4 - |