Changing password - FD70

FD70 Configuration and Maintenance Guide

Document code
M212222EN
Revision
J
Language
English
Product
FD70
Document type
User guide
  • Laptop
  • Maintenance cable
You can change the password of the admin user and the data user. To do that, you need to know the current admin password.
  1. Establish a maintenance connection to FD70.
  2. Log in as an admin user.
    ssh admin@<fixed IP address of FD70>
  3. Change the user level:
    level 1
  4. Change the password.
    CAUTION If you forget the admin password, you cannot retrieve it without factory resetting the device (requires device activation code).
    Follow generic principles in creating a good strong password.
    1. Change the admin user's password:
      set fd.password.admin
    2. Change the data user's password:
      set fd.password.data

      Type the new password and repeat it when prompted.

      Setting the password with the set or getset command is not possible (as in set fd.password.data <password>).

  5. Close the connection.
    close