Make sure that you have the replacement spare part available.
-
Switch off both AC (mains) power switch and battery switch.
Make sure that there is no AC (mains) power available for the system.
- Disconnect the cable from the connector on the sensor.
- If the cable is attached with cable ties to the mast and/or sensor support arm, remove the cable ties.
- In the interface unit, loosen the cable from the cable gland.
- Disconnect the wires from the connector and remove the cable.
- Route the replacement cable through the cable gland.
-
Connect the wires of the replacement cable in the connectors.
The board includes markings to indicate how to connect the wires. HMP155 wiring Wire Color Description Red GND Blue Vin+ − VH+(F1) − VH−(F1) Brown COM3A− Pink COM3B+ LM21 wiring Wire color Description Gray GND Pink Vin+ White VH+(F2) Brown VH−(F2) Yellow COM3A− Green COM3B+ − D/N − GND - Route the cable from the interface unit to the sensor, attaching the cable with cable ties to the mast and/or sensor support arm.
- Power up the system.
- Verify operation.