Replacing mounting frame - FD70

FD70 Configuration and Maintenance Guide

Document code
M212222EN
Revision
J
Language
English
Product
FD70
Document type
User guide
  • Cable ties
  • Flathead screwdriver
  • Set of Allen keys
  • Set of wrenches
  • Spirit level

Make sure that you have the replacement spare part available.

  1. Switch off both AC (mains) power switch and battery switch.

    Make sure that there is no AC (mains) power available for the system.

  2. Remove the humidity and temperature probe and the background luminance sensor. Remove their cables and remove their sensor support arms from the mounting frame.
  3. Remove the radiation shield and cabling box.
  4. Disconnect the measurement unit and obstruction light cables as needed, for example, if the cables are routed through the mounting frame.
  5. Remove the mounting frame from the mast.
  6. Remove the interface unit and Termbox from the mounting frame.
  7. Mount the interface unit and Termbox on the replacement mounting frame.

    For Termbox mounting instructions, see Replacing termination box.

  8. Follow the installation instructions in FD70 Installation Guide (M212221EN).
  9. Power up the system.
  10. Verify operation.