When starting to use FD70, define the device identifier and device location information.
This information helps to distinguish several devices from each other and provides metadata for the measurements.
The configurable unit metadata settings are listed in the following table. Use the settings that are suitable for you.
Parameter | GET | SET | Description | Value / Range | Default |
---|---|---|---|---|---|
fd.unit.deviceid | 0 | 1 |
Device identifier In MES 7 and MES 8, known as unit identifier. |
|
− |
fd.unit.alias1 | 0 | 1 | Alias name 1, max. 80 characters | Freeform text | − |
fd.unit.alias2 | 0 | 1 | Alias name 2, max. 80 characters | Freeform text | − |
fd.unit.latitude | 0 | 1 |
Latitude Unit: degrees |
−90.000000 … 90.000000 | 0.0 |
fd.unit.longitude | 0 | 1 |
Longitude Unit: degrees |
−180.000000 ... 180.000000 | 0.0 |
fd.unit.altitude | 0 | 1 |
Altitude Unit: meters Resolution: full meters Use negative value (-) for values below sea level |
−999 ... 9999 | 0 |