Table 1. Status information
Bit 1 Message Value Description
0

Not ready to measure

0 = Ready

1 = Not ready

Unit is starting up. When unit reaches full operational status, the flag is cleared. Measurement data may be invalid.

If the condition persists, check error bits.

1 Reference setting ongoing

0 = Not ongoing

1 = Ongoing

If reference setting does not start, check status information bits 10–13 and error bits.
2 Laser temperature change in progress

0 = Not ongoing

1 = Ongoing

Unit operational, but measurement data may be invalid.

Wait for laser temperature change to finish.

If the condition persists, check error bits.

3 Window contamination warning 2

0 = OK

1 = Contaminated

Window is getting contaminated. Clean the window.
4 Window heating

0 = OK

1 = Not working

If heating is not working, monitor window contamination.
5 Low input voltage detected

0 = Voltage OK

1 = Voltage low

Unit operational, but check input voltage.
6 High input voltage detected

0 = Voltage OK

1 = Voltage high

7 High internal temperature detected

0 = Temperature OK

1 = Temperature high

First notification of unit getting too hot.
8 Temperature unit

0 = °C

1 = °F

9 Layer thickness unit

0 = mm

1 = inch

10 Reference setting interrupted due to laser temperature change

0 = False

1 = True

Repeat reference setting when laser temperature change has finished.
11

Reference setting interrupted due to hardware error, check parameter 0x56

0 = False

1 = True

Check error bits and parameter 0x56, which contains reason for error.
12 Reference setting values are not updated due to poor signal quality

0 = False

1 = True

Excessive variation in road surface type. Find more representative road surface.
13 Reference setting was interrupted by client

0 = False

1 = True

14 Signal levels low, uncertainty in surface layer thickness results

0 = False

1 = True

Unit operational, but measurement data may be invalid.

Verify installation and clean window.

15 Road surface type significantly different from road surface type used in reference setting

0 = False

1 = True

Unit is operational, but measurement data can be invalid. If condition persists, perform reference setting.
16 Layer thickness result produced undefined result

0 = False

1 = True

Verify installation. If condition persists, perform reference setting.
17 Measurement over range, layer thickness measurement range exceeded

0 = False

1 = True

Maximum reported layer thickness 60 mm (2.36 in) exceeded. If this does not represent actual conditions, perform reference setting.
18–31 Reserved for future use -

Reference setting cannot be started if status info bit 0, 1, or 2 is set.

Laser temperature change stops the ongoing reference setting.

1 Bit is shown in MD30 interface response data message, not in RoadAI.
2 Reported by MD30 models that have the window contamination feature.