Stop reference setting - MD30

MD30 Interface Description

Document code
M212201EN
Revision
E
Language
English
Product
MD30
Document type
Technical description

The stoprefs command sends the STOP REFERENCE SETTING message to the unit.

Example

The reference setting is started and it is checked that it is actually ongoing. After the stoprefs command the reference setting is no longer ongoing and it is indicated that the reference setting was interrupted by the client.

/> setrefs 1
/> Unit ID: 1, Client ID: 0, ID: 0x30, Nb: 7, Len: 11, icd_version: D, Err: 0
Success: 1, Status info: 0x00000000, Error bits: 0x00000000

/> getunitstatus
/> Unit ID: 1, Client ID: 0, ID: 0x12, Nb: 8, Len: 10, icd_version: D, Err: 0
Status info: 0x00000002, Error bits: 0x00000000

/> stoprefs
/> Unit ID: 1, Client ID: 0, ID: 0x32, Nb: 9, Len: 2, icd_version: D, Err: 0
Stop reference setting ack

/> getunitstatus
/> Unit ID: 1, Client ID: 0, ID: 0x12, Nb: 10, Len: 10, icd_version: D, Err: 0
Status info: 0x00002000, Error bits: 0x00000000