SET PARAMETER request - MD30

MD30 Interface Description

Document code
M212201EN
Revision
D
Language
English
Product
MD30
Document type
Technical description

Format

<message start> <message sender ID> <message receiver ID> <message ID> <message number> <data length> <parameter ID> <parameter value> <CRC>
Field

Offset

Size in bytes

Message start

0 1

Message sender ID

1 1

Message receiver ID

2 1

Message ID

3 1

Message number

4 1

Data length

5 ... 6 2
Parameter ID 7 ... 8 2
Parameter value 9 ... 12 4

CRC

13 ... 14 2

Example

The configured parameter is 0x41, air temperature offset correction.

0xab 0x00 0x01 0x41 0x12 0x06 0x00 0x41 0x00 0x00 0x00 0x40 0x3f 0x7d 0xb1
Field Bytes Value

Message start

0xab 0xab

Message sender ID

0x00 0

Message receiver ID

0x01 1

Message ID

0x41 0x41

Message number

0x12 18

Data length

0x06 0x00 6
Parameter ID 0x41 0x00 0x41 = air temperature offset
Parameter value 0x00 0x00 0x40 0x3f 0.75

CRC

0x7d 0xb1 -