PJB480 Parts - PJB480

PJB480 Installation and Maintenance Guide

Document code
M212200EN
Revision
B
Language
English
Product
PJB480
Document type
User guide
Figure 1. PJB480, Parts within Enclosure
1
Power switch
2
Circuit breaker (2 pcs)
3
Surge protector, 230 V
4
Power supply, 24 VDC (2 pcs)
5
Fuse, 2 A, 5 × 20 mm (0.79 in)
6
Mains filter

In addition to items in the delivery, you need the following:

  • AC (mains) cable with a minimum cross-section of 3 × 1.5 mm2 (15 AWG)
  • An external disconnection device (for example, a circuit breaker) for the AC (mains) power connection
  • APPK-SET mounting kit for mast installation (optional)
  • Signal cable with a minimum of 3 wires and a cross‑section of 0.25 mm2 ... 1.5 mm2 / AWG 24 ... AWG 16 (for connecting PJB to weather station, optional)
Since the cables used may vary, PJB480 includes cable glands for fitting different sizes of cables.
Select the cable gland based on the size of the cable you are using.
Figure 2. PJB480 Enclosure Parts
Number in Figure Part Purpose
1 Cable gland M16×1.5 (2 pcs)

For cable diameter range 5 ... 10 mm (0.20 ... 0.39 in).

AC (mains) cable typically fits this cable gland.

2 Cable gland M32×1.5 (2 pcs) For cable diameter 18 ... 25 mm (0.71 ... 0.98 in).
3 Cable gland M20×1.5 (1 pc)

For cable diameter range 6 ... 12 mm (0.24 ... 0.47 in).

Wind sensor cables CBL210706-2M and CBL210706-10M fit this cable gland.

4 Cable gland M25×1.5 (3 pcs)

For cable diameter range 9 ... 16 mm (0.35 ... 0.63 in).

5 Reservation for a cable gland (1 pc) For adding an optional 40 mm (1.57 in) cable gland.
6 Connector (1 pc) For connecting the grounding cable.