The WMT704 wind sensor extends the measurement range of the WMT700 series to 90 m/s. To get WMT704, you must place an order. Older versions cannot be upgraded to WMT704 in the field.

The WMT700 series offers the following measurement ranges:

Table 1. WMT700 Series Measurement Ranges
Model Measurement range Reporting range
WMT701 0 … 40 m/s 0 … 50 m/s
WMT702 0 … 65 m/s 0 … 75 m/s
WMT703 0 … 75 m/s 0 … 100 m/s
WMT704 0 … 90 m/s 0 … 100 m/s

When the wind speed exceeds the measurement range, WMT700 gives an alarm. The sensor shows the measurement, but the accuracy is unspecified.

Table 2. Accuracy inside Measurement Range
Range Accuracy
0 … 75 m/s ±0.1 m/s or 2 % of the reading, whichever is greater
75 … 90 m/s ±5 %