Configuring MOG100 for NM10 - NM10 - MOG100

MOG100 Configuration Guide

Document code
M212056EN
Revision
C
Language
English (United States)
Product
MOG100
Document type
User guide

You can configure measurement data transfer from the air quality and weather transmitters to NM10 using MOG100.

When using MOG100 with NM10, you must configure the address where MOG100 sends the data.

  1. On your computer, select Start > AQ Tool.
  2. To connect to the device, select Connect in AQ Tool.
  3. MOG100 sends data to the addresses that are defined in Configuration. Set the following:
    AQ-View address #1 <NM10 IP address>

    AQ-View address #2 <NM10 IP address>

    AQ-View address #3 <NM10 IP address>

  4. In NM10, set the ports for listening and saving data that comes from MOG100. Go to the following address and check the MOG100 endpoint in the NM10 application:

    https://<localhost>:8181/jdcp-webapp/endpoints/mog/100. Replace localhost with the actual server name or IP address.

    To verify the URL of the service, see Vaisala Observation Network Manager NM10 User Guide.

    The URL of the service can change in different NM10 versions.
  5. Check that MOG100 is registered in NM10:
    • In NM10 at https://<server name or IP address>/nm10/desktop, go to Network Status > Communication Devices or Network Status > Observation Sites and check that MOG100 is on the list.
    • In the NM10 events list, there is a new event informing that a site configuration was created for the MOG100 device.
    • If you want to view or change the site configuration, see Vaisala Observation Network Manager NM10 User Guide.
    Use the serial number of MOG100 as the site name in NM10.