The reference calculation in this example is
based on the following criteria:
- Gust wind speed of 50 m/s at the top of
the mast
- 10‑meter mast with 1 set of guy
wires
Figure 1. Example 2: Mast assembly in reference
wind load calculation
Table 1. Example 2: Wind load calculation for
mast concrete foundation
Parameters |
Description |
Example 1: Maximum vertical load |
Example 2: Maximum overturning moment |
Nd |
Normal force |
−6.5 kN (down) |
−4.4 kN (down) |
Qd |
Shear force |
−0.5 kN |
1.9 kN |
Md |
Overturning moment |
−0.8 kNm |
2.8 kNm |
Table 2. Example 2: Wind load calculation for guy
wire concrete foundation
Parameters |
Description |
Example 1: Maximum guy wire tension |
Nk |
Normal force |
3.5 kN (up) |
Qk |
Shear force |
2.1 kN |
Mk |
Moment |
0 kNm |
Table 3. Example 2: Mast calculation
weights
Part |
Weight |
Mast |
35 kg (77.2 lb)
|
Enclosure with weather station electronics |
40 kg (88.2 lb) |
Support arm |
5 kg (11.0 lb) |
Solar panel |
3.5 kg (7.7 lb) |
Antenna |
1 kg (2.2 lb) |
Obstruction light |
2 kg (4.4 lb) |
Lightning protection (air terminal) |
2 kg (4.4 lb) |
Sensor |
2 kg (4.4 lb) |
Table 4. Example 2: Mast calculation concrete
values
Description |
Value |
Concrete volume |
0.41 m3 |
Concrete weight |
10.1 kN |
Net pressure of soil |
≥ 70 kN/m2 |
Groundwater |
No |