When you have performed necessary installation or maintenance tasks, erect the mast.
| WARNING For safety reasons, do
not operate the winch alone. |
-
Place the winch handle on the lower lever. To lock the handle in place, turn it.
-
To check that the wire is tight and the winch is firmly in place, pull the wire.
-
Check that the grounding wire and sensor cables do not get caught between the lifting
rod or mast hinge.
-
Before erecting the mast, check that the screws and washers of the guy wire flange are
tight and that guy wires 2 and 3 are secure.
-
Start winching.
| WARNING Never go under the mast
when the winch is operated or when the mast is in a tilted position and supported only
by the winch wire. |
| WARNING Make sure nobody is in
the danger zone when you use the winch. |
| WARNING Make sure that the winch
wire does not get tangled or cause someone to trip and fall. |
| CAUTION Make sure that the winch
wire does not bend. Keep the winch wire straight or in coil. |
-
If you stop winching while erecting the mast, always lock the wire rope by pressing the
T‑handle towards the rope guide sleeve.
-
When the mast is almost upright, check that the mast bolts are aligned with the holes
in the mast base plate.
-
When the winch wire becomes loose, pull the mast to an upright position.
-
Lock the mast with the washers and nuts. Tightening torque 100 Nm.
| CAUTION Do not attach the
washer and nut to the foundation bolt where you install the down conductor. |
- 1
- Hex nut ISO4032 M20 (2 pcs)
- 2
- Washer DIN125 A21 (2 pcs)