RSI51 specifications - RSI51

RSI51 Installation Manual

Document code
M211863EN
Revision
B
Language
English
Product
RSI51
Document type
User guide
Table 1. Operating environment
Property Description/Value

Operating environment

Indoor use

Use in wet location

No

Operating temperature

−20 … +55 °C (−4 … +131 °F)

Storage temperature

−40 … +65 °C (−40 … +149 °F)

Operating humidity

0 … 100 %RH, non‑condensing

Storage humidity

0 … 100 %RH, non‑condensing

Pollution degree

2

Maximum operating altitude

3000 m (approx. 9800 ft)

Table 2. Inputs and outputs
Property Description/Value
Input voltage 100 … 240 V AC, ±10 %
Input frequency 50 … 60 Hz
Input current 100 mA
Surge protection Input electricity, input closing contacts, output serial (RS‑485/RS‑232)
Overvoltage category II
Data input options

8 × closing contact from manual switch or relay

12 … 48 DC voltage message

Data output options Serial (RS‑485/RS‑232), Ethernet/LAN
Service connection Serial RS‑232
Table 3. Compliance
Property Description/Value

EU directives

Low Voltage Directive (2014/35/EU)

EMC Directive (2014/30/EU)

RoHS Directive (2011/65/EU) amended by 2015/863

EMC compatibility

EN 61326‑1, industrial environment

Electrical safety

EN 61010‑1

Cold

IEC 60068‑2‑1

Dry heat

IEC 60068‑2‑2

Damp heat, cyclic

IEC 60068‑2‑30

Vibration

ETSI EN 300 019‑2‑2

Compliance marks

CE, RCM
Table 4. Mechanical specifications
Property Description/Value
Dimensions (H × W × D) 216 × 360 × 111 mm (8.50 × 14.17 × 4.37 in)
Weight 3.5 kg (7.72 lb)
Enclosure material Polycarbonate (PC), light gray RAL7035
Mounting options

DIN‑rail mounting kit included in the delivery

Wall-mounting screws not included