Gas level alert registers are 16-bit fields. Each register communicates the status of alerts of specific severity for a particular timeframe (for example, gas level caution alerts for present values).

If an alert is active, the corresponding bit is set to 1. The bit is set to 0 when the alert is deactivated, turned off, or gas level alerts are muted. For more information, see Gas level alerts.

Table 1. Alert registers (read-only)
Register number Address Register description Data format Bit order
11 0x000A Gas level caution alerts for present values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

8 = Moisture in oil

9 = Relative moisture in oil

11 = TGP above maximum limit

12 = TGP below minimum limit

15 = Any caution alert active

12 0x000B Gas level caution alerts for 24 hour average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any caution alert active

13 0x000C Gas level caution alerts for 7 day average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any caution alert active

14 0x000D Gas level caution alerts for 30 day average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any caution alert active

15 0x000E Gas level alarms for present values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

8 = Moisture in oil

9 = Relative moisture in oil

11 = TGP above maximum limit

12 = TGP below minimum limit

15 = Any alarm active

16 0x000F Gas level alarms for 24 hour average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any alarm active

17 0x0010 Gas level alarms for 7 day average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any alarm active

18 0x0011 Gas level alarms for 30 day average ROC values 16-bit field

0 = Methane

1 = Acetylene

2 = Ethylene

3 = Ethane

4 = Carbon monoxide

5 = Carbon dioxide

6 = TDCG

7 = Hydrogen

15 = Any alarm active