Basic features and options - OPT100

OPT100 User Guide

Document code
M211858EN
Revision
AA
Language
English
Product
OPT100
Document type
User guide
  • Measurement of seven fault gases, moisture in oil, and total gas pressure
  • Several calculated parameters and gas ratios available
  • Ethernet and RS-485 interfaces for SCADA integration
  • Modbus protocol (RTU and TCP)
  • Protocol test mode for verifying SCADA integration
  • Three configurable relay outputs
  • Gas level alerts for measured values and rate of change (ROC)
  • IP66 rated cabinet
  • Optional software features:

    • DGA diagnostics using Duval triangles
    • DNP3 (Distributed Network Protocol) over Ethernet or RS-485
    • IEC 61850 protocol over Ethernet
  • Installation options:

    • Ground mounting set
    • Antivibration ground mounting set
    • Wall mounting set
    • Weather shield
  • Device liquid type options:
    • Mineral oil
    • Synthetic ester liquid
    • Natural ester liquid