0WF!0WF,g=A,l=N,t=A,0=273.00,1=273.01,2=273.00,3=273.00,4=273.00,5=273.00,a=45.1,b=50.2,u=54.9,v=63.1,x=65.1,y=65.1<cr><l f>
Table 1. Wind configuration settings
Field character Field name Description
g Strategy

A = All

N = North

E = East

S = South

l Pulse length

N = Normal, auto

A = Adjusted on half

S = Short

E = Extended

T = Test

t Single transducer mode

A = All

N = North

E = East

S = South

0..5 Zero adjustment 1 … 655.35 us (default 273.00 us)
a, b Detect level btw. N and E 0 … 100 % (default 70 %)
u, v Detect level btw. E and S 0 … 100 % (default 70 %)
x, y Detect level btw. S and N 0 … 100 % (default 70 %)