PTU measurement sampling - WXT530

WXT530 Series User Guide

Product status
Document code
M211840EN
Revision
G
ft:locale
en-US
Product
WXT530
Document type
User guide
Table 1. PTU measurement
Quantity​ Qualifier​ Update interval​ Averaging period​

Air temperature​

[°C] [°F]​

Instant​

10 sec​

Media filtered ​instant of 3 samples​

Min./Max. 1 ... 10 min 10 sec instants over average period
Average

1 ... 10 min / 1 min steps​

Change in holding register address 0x0002

Absolute air pressure​

[hPa]​

Instant​

10 sec​

Media filtered 1 sec ​instant of 3 samples​

Min./Max.​ 1 ... 10 min 10 sec instants over average period
Average

1 ... 10 min / 1 min steps​

Change in holding register address 0x0003

Relative air humidity​

[%RH]​

Instant​

10 sec​

Media filtered ​1 sec instant of 3 samples​

Min./Max.​ 1 ... 10 min 10 sec instants over average period
Average

1 ... 10 min / 1 min steps​

Change in holding register address 0x0002