This command requests a combined data message with user-configurable set of wind, pressure, temperature, humidity, precipitation, and supervisor data.
Command format:
aR0<cr><lf>
| a | Device address (default = 0) |
| R0 | Composite message query command |
| <cr><lf> | Command terminator |
Example of the response (you can select the parameters included from the full parameter set of the commands aR1, aR2, aR3, and aR5):
0R0,Dx=005D,Sx=2.8M,Ta=23.0C,Ua=30.0P,Pa=1028.2H, Rc=0.00M,Rd=10s,Th=23.6C<cr><lf>