Polling with CRC - WXT530

WXT530 Series User Guide

Product status
Document code
M211840EN
Revision
G
ft:locale
en-US
Product
WXT530
Document type
User guide

Use the same data query commands as in the previous sections but type the first letter of the command in lower case and add a correct three-character CRC before the command terminator. The response also contains a CRC.

Command format for requesting a wind data message with a CRC

ar1xxx<cr><lf>
a Device address
r1 Wind message query command
xxx Three-character CRC for ar1 command
<cr><lf> Command terminator
Example of the response (the parameter set is configurable):
0r1,Dn=236D,Dm=283D,Dx=031D,Sn=0.0M,Sm=1.0M,Sx=2.2MLFj<cr><lf>

The three characters before <cr><lf> are the CRC for the response.

To request the correct CRC for each command, type the command with an arbitrary three-character CRC.

Example of asking the CRC for the wind data message query ar1:

Command format:

ar1yyy<cr><lf>
a Device address
r1 Wind message query command
yyy Arbitrary three-character CRC
<cr><lf> Command terminator

Response:

atX,Use chksum GoeIU~<cr><lf>
a Device address (default = 0)
tX,Use chksum Text prompt
Goe Correct three-character CRC for the ar1 command
IU~ Three-character CRC for the response message
<cr><lf> Response terminator

Example of the other data query commands with CRC (when the device address is 0):

Parameter Description
Pressure, humidity and temperature message query 0r2Gje<cr><lf>
Precipitation query 0r3Kid<cr><lf>
Supervisor query 0r5Kcd<cr><lf>
Combined message query 0rBVT<cr><lf>
Composite data message query 0r0Kld<cr><lf>

In every case the response contains a three-character CRC before the <cr><lf>.