PTU measurement sampling - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide
Table 1. PTU measurement
Quantity​ Qualifier​ Update interval​ Averaging period​

Air temperature​

[°C] [°F]​

Instant​

10 sec​

Media filtered ​instant of 3 samples​

Min/Max 1 min 10 sec instants over average period
Change in holding register 0x0002​ Average​ 1 min​ 1 – 10 min / 1 min steps (1 min averaged 10 sec instants)​

Abs. air pressure​

[hPa]​

Instant​

10 sec​

Media filtered ​instant of 3 samples​

Min/Max​ 1 min 10 sec instants over average period
Change in holding register 0x0003​ Average​

Min/Max

1 min​ 1 – 10 min / 1 min steps (1 min averaged 10 sec instants)​

Relative air humidity​

[%RH]​

Instant​

10 sec​

Media filtered ​instant of 3 samples​

Min/Max​ 1 min 10 sec instants over average period
Change in holding register 0x0002​ Average​

Min/Max

1 min​ 1 – 10 min / 1 min steps (1 min averaged 10 sec instants)​