At the measurement site, you must mount, ground, align, and connect the transmitter to the data logger and the power source.

You can install the instrument on top of a pole mast or on a support arm.

For the most reliable measurements:

  • Avoid trees or other objects nearby which could disturb wind flow.
  • Install the sensor to the height that best represents the prevailing wind conditions on site.
CAUTION To prevent equipment damage, install an air terminal so that the tip is as high above the instruments and sensors as possible.
To prevent corrosion, oxidation, and seizing, use a non‑conductive, non‑water‑soluble, non‑silicone‑based grease, such as ceramic or Teflon paste, between different kinds of metal.