Mounting WXT530 on sensor support arm - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide
10‑mm wrench

If you use the optional mounting kit, you only need to align the sensor when mounting it for the first time.

CAUTION Handle with care. Any impact on the instrument or sensor array may cause damage and lead to incorrect measurements.
  1. Remove the screw cover.
  2. Align the sensor support arm in South–North direction.

    If you cannot align the sensor support arm, adjust the wind direction offset.

  3. Mount the transmitter on the sensor support arm.
    1
    Nut M6 DIN 934
    2
    Mounting bolt M6 DIN 933
    3
    Screw cover
    1
    Mounting bolt M6 DIN 933
    2
    Nut M6 DIN 934