Checking current communication settings (aXU) - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide

Use this command to request the current communication settings.

Command format in ASCII and NMEA 0183:

aXU<cr><lf>

Command format in SDI-12:

aXXU!
Parameter Description
a Device address, which can consist of the following characters: 0 (default) ... 9, A ... Z, a ... z.
XU Device settings command in ASCII and NMEA 0183
XXU Device settings command in SDI-12
<cr><lf> Command terminator in ASCII and NMEA 0183
! Command terminator in SDI-12

Example response in ASCII and NMEA 0183:

aXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S], L=[L],N=[N],V=[V],H=[H],O=[O]<cr><lf>

Example response in SDI-12:

aXXU,A=a,M=[M],T=[T],C=[C],I=[I],B=[B],D=[D],P=[P],S=[S], L=[L],N=[N],V=[V],H=[H],O=[O]<cr><lf>
You can add the Id information field in the supervisor data message to provide identifying information in addition to the transmitter address. The information field is set as part of the factory settings. You can only modify it with the Vaisala Configuration Tool.