Checking the settings (aTU) - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide

Use this command to check the current pressure, temperature, and humidity sensor settings.

Command format in ASCII and NMEA 0183:

aTU<cr><lf>

Command format in SDI-12:

aXTU!
Name Description
a Device address
TU Pressure, temperature and humidity sensor settings command in ASCII and NMEA 0183
XTU Pressure, temperature and humidity sensor settings command in SDI-12
<cr><lf> Command terminator in ASCII and NMEA 0183
! Command terminator in SDI-12

The response in ASCII and NMEA 0183:

aTU,R=[R],I=[I],P=[P],H=[H]<cr><lf>

The response in SDI-12:

aXTU,R=[R],I=[I],P=[P],H=[H]<cr><lf>

[R][I][P][H] are the setting fields.

Example (ASCII and NMEA 0183, device address 0)

0TU<cr><lf>
0TU,R=11010000&11010000,I=60,P=H,T=C,N=T<cr><lf>

Example (SDI-12, device address 0)

0XTU!0XTU,R=11010000&11010000,I=60,P=H,T=C,N=T<cr><lf>