Precipitation intensity reset (aXZRI) - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide

This command resets the rain and hail intensity parameters Ri, Rp, Hi, and Hp.

Command format in ASCII and NMEA 0183:

aXZRI<cr><lf>

Command format in SDI-12:

aXZRI!
a Device address
XZRI Precipitation intensity reset command
<cr><lf> Command terminator in ASCII and NMEA 0183
! Command terminator in SDI-12
The precipitation counter and precipitation intensity parameters are reset also when the supply voltage is disconnected, the command aXZ is issued, precipitation counter reset mode is changed, or when the precipitation/surface hits units are changed.

Example (ASCII):

0XZRI<cr><lf>

0TX,Inty reset<cr><lf>

Example (SDI-12):

0XZRI!0<cr><lf> (= device address)

Example (NMEA 0183):

0XZRI<cr><lf>

$WITXT,01,01,11,Inty reset*39<cr><lf>