Abbreviations and units - WXT530

WXT530 Series User Guide

Document code
M211840EN
Revision
F
Language
English (United States)
Product
WXT530
Document type
User guide
Table 1. Abbreviations and units
Abbreviation Name Unit Status 1
Sn Wind speed minimum m/s, km/h, mph, knots #, M, K, S, N
Sm Wind speed average m/s, km/h, mph, knots #, M, K, S, N
Sx Wind speed maximum m/s, km/h, mph, knots #, M, K, S, N
Dn Wind direction minimum deg #, D
Dm Wind direction average deg #, D
Dx Wind direction maximum deg #, D
Pa Air pressure hPa, Pa, bar, mmHg, inHg #, H, P, B, M, I
Ta Air temperature °C, °F #, C, F
Tp Internal temperature °C, °F #, C, F
Ua Relative humidity %RH #, P
Rc Rain accumulation mm, in #, M, I
Rd Rain duration s #, S
Ri Rain intensity mm/h, in/h #, M, I
Rp Rain peak intensity mm/h, in/h #, M, I
Hc Hail accumulation hits/cm2, hits/in2, hits #, M, I, H
Hd Hail duration s #, S
Hi Hail intensity hits/cm2h, hits/in2h, hits/h #, M, I, H
Hp Hail peak intensity hits/cm2h, hits/in2h, hits/h #, M, I, H
Th Heating temperature °C, °F #, C, F
Vh Heating voltage V #, N, V, W, F 2
Vs Supply voltage V #, V
Vr 3.5 V ref. voltage V #, V
Id Information field alphanumeric
1 The letters in the status field indicate the unit, the # character indicates invalid data.
2 For heating # = heating option is not available (has not been ordered).

N = heating option is available but have been disabled by user or the heating temperature is over the high control limit.

V = heating is on at 50% duty cycle and the heating temperature is between the high and middle control limits.

W = heating is on at 100% duty cycle and the heating temperature is between the low and middle control limits.

F = heating is on at 50% duty cycle and the heating temperature is below the low control limit.