Lightning protection kit - DKE110F

DKE110F User Guide

Document code
M211788EN
Revision
F
Language
English
Product
DKE110F
Document type
User guide
CAUTION Vaisala recommends an air terminal for all mast structures that reach 10 meters (33 feet). For mast structures that reach 6 meters (20 feet) or lower, an air terminal is recommended in regions with high lightning density. Especially in tropical or sub-tropical regions, a lightning protection system is a necessity.

Lightning Protection Kit DKL201 includes an air terminal, brackets, a groove connector, and a down conductor. The air terminal and the down conductor are made of aluminum.

The air terminal helps to protect the equipment installed on the mast from overvoltage when lightning occurs.

Figure 1. Lightning protection kit DKL201
1
Air terminal
2
Bracket with installation accessories
3
Down conductor
4
Groove connector