Lightning protection kit DKL201 is suitable for the following Vaisala masts with a diameter
of 60 mm (2.36 in) at the top:
- Vaisala DKE100 Series Guyed Frangible
Mast
- Vaisala DKE200 Series Frangible Lattice
Mast
- Vaisala DKP200 Series Tiltable Pole
Mast
- Vaisala Long Pole Mast DKP110
Figure 1. DKL201 kit for 60‑mm (2.36‑in)
mast
- 1
- Hex screw M6×45 DIN933 A4 (9 pcs)
- 2
- Air terminal bracket (2 pcs)
- 3
- Flat washer A6.4 DIN125 A4 (18 pcs)
- 4
- Spring washer B6 DIN127 A4 (9 pcs)
- 5
- Hex nut M6 DIN934 A4 (9 pcs)
-
Place the air terminal brackets on both sides of the mast. The installation height is
30 cm (11.8 in) from the top of the mast.
| CAUTION To prevent equipment
damage, install the air terminal so that its tip is as high above the sensors as
possible. |
| CAUTION Position the air
terminal bracket so that the mast down conductor and the other cables can be routed down
on the opposite sides of the mast. |
-
Install all the screws except the one on the top right corner of
the brackets. Do not tighten the screws yet.
- 1
- Hex nut M6 DIN934 A4
- 2
- Spring washer B6 DIN127 A4
- 3
- Flat washer A6.4 DIN125 A4
- 4
- Flat washer A6.4 DIN125 A4
- 5
- Hex screw M6×45 DIN933 A4
-
Install the air terminal between the screws so that the bent lower
end of the air terminal comes out from between the upper screws.
-
Install the remaining screw, washers, and nut.
-
Tighten all 9 screws.