Property | Description/Value |
---|---|
Precipitation | Liquid |
Accuracy | 2 % at 1 l/h (0.26 gal/h) |
Diameter of aperture | 225 mm (8.86 in) |
Area of aperture |
400 cm2 (62 in2) With expander unit: 1000 cm2 (155 in2) |
Rainfall capacity | Unlimited |
Resolution |
0.2 mm (0.008 in) (standard) 0.1 mm (0.004 in) (optional) 0.5 mm (0.02 in) (optional) |
Closure time | < 100 ms (for 0.2 mm / 0.008 in of rain) |
Property | Description/Value |
---|---|
Operating temperature |
RG13: +1 ... +85 °C (+33.8 ... +185 °F) RG13H: −20 ... +85 °C (−4 ... +185 °F) |
Storage temperature | −40 ... +85 °C (−40 ... +185 °F) |
Heating (RG13H) | |
Heating connection/disconnection at | +4 °C (+39 °F) |
Heating power |
RG13H: 33W / 48 VDC RG13J: 33W / 24 VDC |
Property | Description/Value |
---|---|
Dimensions (H × Ø) | 338 × 248 mm (13.31 × 9.76 in) |
Weight | 2.6 kg (5.73 lb) |
Material | |
Base, septum ring | Aluminum alloy LM25 |
Outer ring, funnel | Aluminum alloy sheet |
Inlet/Outlet ports, pins | Stainless steel |
Tipping mechanism | Injection-moulded plastic |
Transducer | Reed switch |
Output | |
Circuit | Contact closure |
Connection | Screw terminal |
Life (operations) | 108 closures |