RG13(H) specifications - RG13 - RG13H

RG13 and RG13H User guide

Document code
M211724EN
Revision
E
Language
English
Product
RG13
RG13H
Document type
User guide
Table 1. Measurement performance
Property Description/Value
Precipitation Liquid
Accuracy 2 % at 1 l/h (0.26 gal/h)
Diameter of aperture 225 mm (8.86 in)
Area of aperture

400 cm2 (62 in2)

With expander unit: 1000 cm2 (155 in2)

Rainfall capacity Unlimited
Resolution

0.2 mm (0.008 in) (standard)

0.1 mm (0.004 in) (optional)

0.5 mm (0.02 in) (optional)

Closure time < 100 ms (for 0.2 mm / 0.008 in of rain)
Table 2. Operating environment
Property Description/Value
Operating temperature

RG13: +1 ... +85 °C (+33.8 ... +185 °F)

RG13H: −20 ... +85 °C (−4 ... +185 °F)

Storage temperature −40 ... +85 °C (−40 ... +185 °F)
Heating (RG13H)
Heating connection/disconnection at +4 °C (+39 °F)
Heating power

RG13H: 33W / 48 VDC

RG13J: 33W / 24 VDC

Table 3. Mechanical specifications
Property Description/Value
Dimensions (H × Ø) 338 × 248 mm (13.31 × 9.76 in)
Weight 2.6 kg (5.73 lb)
Material
Base, septum ring Aluminum alloy LM25
Outer ring, funnel Aluminum alloy sheet
Inlet/Outlet ports, pins Stainless steel
Tipping mechanism Injection-moulded plastic
Transducer Reed switch
Output
Circuit Contact closure
Connection Screw terminal
Life (operations) 108 closures
Figure 1. RG13(H) dimensions