Connecting to service port - HMD110 - HMD112 - HMS110 - HMS112 - HMW110 - HMW112 - TMD110 - TMW110

HMDW110 Quick Guide

Document code
M211692EN
Revision
D
Language
English
Product
HMD110
HMD112
HMS110
HMS112
HMW110
HMW112
TMD110
TMW110
Document type
User guide

Before connecting the transmitter to a PC:

  • If the terminal block for terminals 5 ... 8 is wired, pull it out. This disconnects the transmitter from supply voltage and prevents possible equipment damage that may be caused by ground loops. The locations of the terminal blocks and the service port are shown in HMDW110 series component boards.
  • If the other terminal block is wired (terminals 1 ... 4), pull it out also. This prevents the communication between the transmitter and the RDP100 remote display panel or Modbus (RS-485) host from interfering with your connection.

The service port is intended for a temporary connection to the transmitter. You can use it for configuration, calibration, and troubleshooting using a computer with Windows operating system. Use Vaisala Insight software to connect to the transmitter. You also need a Vaisala USB cable for computer connection (order code 219690).

The RS-485 line of the service port is shared with the connection to RS-485 Modbus output/output to RDP100 remote display panel; the M8 service port connector is just an additional connector for easier access.

Download Insight software at www.vaisala.com/insight.
For more information and examples of using Vaisala Insight software and serial commands, see HMDW110 Series User Guide (M211726EN) available at www.vaisala.com/hmdw110.