Configuring runway settings - WID513

WID513 User Guide

Document code
M211676EN
Revision
G
Language
English
Product
WID513
Document type
User guide
You can configure the runway settings for pressure calculation.
  1. Enter Maintenance mode.
  2. On the Advanced settings page, press Runway.
  3. On the Runway settings page, to change the settings, press the data fields, and use the typing pad to type the new setting.
    TDZ1 location
    ICAO location indicator for the runway (touchdown zone 1), for example, 04L.
    TDZ1 difference to station height (m)
    Height of the runway (touchdown zone 1) in relation to the station. Value range: −99.99 ... 99.99.
    TDZ2 location
    ICAO location indicator for the runway (touchdown zone 2), for example, 22R.
    TDZ2 difference to station height (m)
    Height of the runway (touchdown zone 2) in relation to the station. Value range: −99.99 ... 99.99.
  4. To save the changes, press Apply.
    The changes are valid only after pressing Apply.