| Wear protective eyewear, gloves, and a safety helmet. |
| To protect your hands, always wear gloves when handling the guy wires. |
| WARNING Make sure your clothing and equipment do not get tangled in the
wires or equipment during installation. |
In assembling guy wires, you need:
- Guy wire
end for 25 to 68 mm2 wire (3 pcs)
Attach the guy wires with the wedge clamps
to the guy wire foundations.
-
Connect the U‑bolt to the lifting eye nut that is installed on the concrete
foundation.
-
Slide the strap onto the U‑bolt and thread the nuts.
-
Push the guy wire through the strap and slide the wedge on the guy wire.
-
Push the wedge to the strap and hammer it in tightly. Check that the wire is
pre-tensioned.
-
To secure the wedge, tighten the wedge adjustment screw.