Removing sensor connectors - RWS200

RWS200 Installation Manual

Product status
Document code
M211608EN
Revision
AA
ft:locale
en-US
Product
RWS200
Document type
User guide
  • (Optional) Flat head screwdriver, maximum size 2.5 mm (0.1 in)
  1. Turn the lock levers to the middle position one by one. You can use your fingers or a flat head screwdriver.
    Using a screwdriver may be helpful especially in tight spaces.
    CAUTION

    Do not pull from the wires or try to remove the connector without first turning the lock levers to the middle position.

    Do not turn the lock levers by force.

    1
    Slot for screwdriver
    2
    Lock lever locked
    3
    Lock lever in the middle position
  2. Remove the connector with your fingers.
    If you need to remove a wire from the connector, push the release button next to the wire with a flat head screwdriver and pull the wire out of the connector. The easiest way to remove a wire from the connector is to do it while the connector is attached to the plug‑in module.