To install the BOXALU‑US or BOXSS‑US
enclosure on a lattice tower, use the 60030004 mounting kit. Install the RWS200 backplate
inside the enclosure using the ASM211177 mounting frame.
For an overview of installation phases and
weights, see BOXALU‑US and BOXSS‑US installation phases and weights .
BOXALU‑US and BOXSS‑US installation
accessories
1
Stainless steel cross member (60030004) (2 pcs)
1.1
⅜ in locking nut SS (8 pcs)
1.2
⅜ × 1 in hex bolt SS (8 pcs)
1.3
⅜ in flat washer SS (8 pcs)
2
BOXALU‑US or BOXSS‑US enclosure
2.1
Crosshead screw ⅜‑16 NC (4 pcs)
2.2
Spring washer (4 pcs)
2.3
Flat washer (4 pcs)
3
Backplate mounting frame
(ASM211177)
3.1
Hex lock nut M6 Wulock Fe/Zn (8 pcs)
3.2
Hex nut M6 Wulock Fe/Zn (8 pcs) (not shown)
4
Standard backplate with electronics
BOXALU‑US and BOXSS‑US
dimensions
Backplate mounting frame
dimensions
Attach the cross members to the lattice tower.
1
Stainless steel cross member (2 pcs) (60030004)
2
⅜ in locking nut SS (4 pcs)
3
⅜ in flat washer SS (4 pcs)
4
⅜ × 1 in hex bolt SS (4 pcs)
Attach the enclosure to the cross members.
Lift the enclosure by holding it from the ceiling and bottom.
1
⅜ in locking nut SS (4 pcs)
2
⅜ in flat washer SS (4 pcs)
3
⅜ × 1 in hex bolt SS (4 pcs)
Drill the necessary cord connector holes and conduit holes to the bottom of the
enclosure.
Example of the layout:
1
1‑inch conduit hole for phone line. Use only if phone line is
installed. Locate as required.
2
2‑inch conduit hole for AC (mains) power cable and enclosure
grounding. Locate as required.
3
2‑inch conduit hole for embedded sensors. Locate as required.
4
½‑inch cord connector (CGB) hole for precipitation sensor. If used,
locate as shown.
5
½‑inch cord connector (CGB) for air temperature and humidity sensor.
If used, locate as shown.
6
½‑inch cord connector (CGB) for wind speed and direction sensor. If
used, locate as shown.
7
Lattice tower
Install the necessary cord connectors and conduits.
The installation contractor supplies the
conduit.
1
½‑inch cord connector (CGB) for
precipitation sensor.
Cord size: .250 ... .375.
2
½‑inch cord connector (CGB) for
air temperature and humidity sensor.
Cord size: .250 ... .375.
3
½‑inch cord connector (CGB) for
wind speed and direction sensor.
Cord size: .250 ... .375.
4
2‑inch conduit, PVC or metal as required, for embedded sensors
5
2‑inch conduit, PVC or metal as required, for AC (mains) power cable
and enclosure grounding
6
1‑inch conduit, PVC or metal as required, for phone line. Use only
if phone line is installed.
7
1‑inch conduit, PVC or metal as required, for disconnect box ground
wire
8
1‑inch conduit, PVC or metal as required, for AC (mains) power
9
100 A breaker box (not supplied)
Assemble the backplate mounting frame and install it inside the enclosure.
You can install the mounting frame
either as shown or upside down, depending on where you want to position the
backplate.
1
BOXALU‑US or BOXSS‑US enclosure
2
Backplate mounting frame
(ASM211177)
3
Crosshead screw ⅜‑16 NC (4 pcs)
4
Spring washer (4 pcs)
5
Flat washer (4 pcs)
Mount the backplate onto the mounting frame.
1
Hex lock nut M6 Wulock Fe/Zn (8 pcs)
2
Standard backplate with electronics