IR illuminators have a fixed 10‑m (33‑ft)
cable. Connect the IR illuminators to the AC/DC power supply.
| WARNING Make sure that you
prepare or connect only de-energized wires. |
| CAUTION Always connect the IR
illuminators to the regular AC/DC power supply, not the additional power supply for WMT700
heating. |
Connecting IR illuminator to AC/DC
power supply
-
Lead the IR illuminator cable through the cabling box and the rubber flange.
-
Connect the cable to the AC/DC power supply terminal according to the following
table.
| Signal |
Wire color |
AC/DC power supply terminal |
Wire color |
Signal |
| Not connected |
– |
dcok |
13 |
– |
Not connected |
| Not connected |
– |
|< |N |
14 |
– |
Not connected |
| +12 … 24 V input (second unit) |
Red |
+ |
– |
Black |
Ground (second unit) |
| +12 … 24 V input (first unit) |
Red |
+ |
– |
Black |
Ground (first unit) |
| Reserved for PMU701 |
– |
+ |
– |
– |
Reserved for PMU701 |
-
Cut or braid the unused wires according to the following table.
| Color |
Usage |
Action |
| White |
Not used |
Cut. |
| Yellow |
| Orange |
Powering |
Braid together and insulate with electrical
tape. |
| Violet |
-
For strain relief, secure the cable to the PMU701 sensor grounding rail with a cable
clamp.